Softwall Cleanrooms

CleanPro® Solutions Softwall Cleanrooms

Our quick-ship and built-to-order softwall clean rooms are easy-to-install with two or more people. The frame is fabricated of white painted steel and each leg has a mounting base to secure it to the floor or to add casters to make your cleanroom portable. The ceiling features an aluminum T-Grid that holds 2' x 4' white vinyl-laminated ceiling panels, 4-lamp cleanroom-sealed light fixtures and fan filter units. The clean room is enclosed by clean vinyl curtain panels and a 4' strip door with 8", 80 mil. clean vinyl strips overlapped by 2".

Request a Softwall Cleanroom Quote:

Get started now-it's easy! Just fill out this quick form and one of our cleanroom experts will help you get started.
Size of Main Room:
Cleanroom Height:
Nominal 9' overall height. An additional 6" clearance is required for proper air flow.
Host Room Height:
Cleanroom Class:
Voltage (FFU):
Lighting:
Curtain Options:
Class 100 requires minimum 60 mil curtains.
Custom Strip Door Size:
Additional Items:   Pre-Wired Frame
  Control Panel
  Magnahelic Gauges
  Casters
  Seismic Zone
  Not Sure
Note: Parameter clearance required: 10" to 12".
Additional Questions:
Contact Information:
First Name:*
Last Name:*
Phone Number:*
Email Address:*
Address:
City:
State:*
Zip Code:
*Required fields. This will not opt you in to any promotional e-mails.

Softwall Cleanroom Diagram
US FED STD 209E & ISO 14644-1 Cleanroom Standards
FED
Class
ISO
Class
Maximum Particles/ft3
≥0.1µm ≥0.2µm ≥0.3µm ≥0.5µm ≥5µm
1 ISO 3 35 7.5 3 1 0.007
10 ISO 4 350 75 30 10 0.07
100 ISO 5 3,500 750 300 100 0.7
1,000 ISO 6 35,000 7,500 3,000 1,000 7
10,000 ISO 7 350,000 75,000 30,000 10,000 70
100,000 ISO 8 3.5 x 106 750,000 300,000 100,000 700
US FED STD 209E was officially cancelled by the General Services Administration of the US Dept. of Commerce on November 29, 2001, but is still widely used.
Curtain panels are pre-engineered to a specific height for proper air flow.
Control panels for operation of fan filter units, lights, and other selected options.
Magnahelic gauges are pressure gauges used to perform a passive depressurization test.
The standard caster package includes swivel casters with brakes, leg stabilizers on three sides or leg gussets. Casters are not recommended for cleanrooms over 12' x 12' or for rooms with more than four legs.
Recommended Filter/Fan Configurations
Room
Dimensions
No. of
Ceiling
Bays
No. of Filter Modules to meet
Fed Std 209 Class Standards
1 10 100 1,000 10,000 100,000
8' x 8' 8 5-8 4-8 3-6 2-3 1-2 1
8' x 12' 12 7-12 6 -12 4-8 3-5 2-3 1-2
8' x 16' 16 10-16 8-16 6-11 4-6 2-4 1-3
12' x 12' 18 11-18 9-18 6-13 5-7 3 -5 1 -3
12' x 16' 24 14 -24 12-24 8-17 6-10 4 -6 2-4
16' x 16' 32 19 -32 16-32 11-22 8-13 5-8 2-5
20' x 20' 50 30-50 25-50 18-35 13-20 8-13 3-8
Assembly: Softwall cleanrooms are shipped knocked down and are easy-to-install with two or more people. Detailed assembly instructions are included.