Prostat PGA-710B

Autoanalysis System Set

Detect, Locate and Identify ESD Events in Your Process

  • Connects to a Field Meter and Charge Plate Monitor
  • Records Walking Voltages per ANSI/ESD STM 97.2 and IEC 61340-4-5
  • Analyzes Offset and Decay Times of Ionizers per ANSI/ESD SP3.3 and ANSI/ESD STM3.1
  • View Voltages in real time on your Computer with the included Autoanalysis Software
  • Professional Reports include Min, Max and Average of Voltage Generation or Decay Times
  • Records and Reports Temperature and Relative Humidity
  • Powered by a Rechargeable Battery
  • Meets requirements of ANSI/ESD S20.20
  • Certificate of Calibration Traceable to NIST included
$2,995.00

What's Included

  • PGA-710B Autoanalysis Meter
  • PGA-710 USB Cable
  • 700AC Analog Cable
  • PGA-710CGL Charge Generation Lead
  • PGA-710CC Input Shorting Shunt
  • PFA-861H Hand Held Electrode
  • Universal Battery Charger
  • Autoanalysis Application Software 2.0
  • Carrying Case

Product Overview

A Data Logger for Advanced Electrostatic Analysis
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.

Create Automatic Detailed Reports
Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities.

The PGA-710B connects to a Field Meter's analog output and computer's USB port using provided cables. The Autoanalysis software converts your instruments into a digital chart recording system with automatic analysis and reporting features.

The PGA-710B will perform measurement and recording functions, provide data analysis, generate charts, then construct and print out complete reports, including the facility's ambient temperature and relative humidity during each test.

Designed for the Walking Test per ANSI/ESD STM97.2 and IEC 61340-4-5
The PGA-710B will calculate the ±3-Sigma ranges of walking and standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times, meeting the requirements of ANSI/ESD STM97.2.

Autoanalysis Application Software 2.0
The PGA-710B's unique software will instantly perform mathematical and statistical functions to assist ESD Program Managers and Plant Auditors in defining strengths and weaknesses of the ESDS device transport and handling process.

Compatible with Windows 10
The PGA-710B is a versatile instrument whose use and benefits are limited only by one's imagination. The PGA-710B is now compatible with 32-bit and 64-bit version of Windows from XP all the way to Windows 10.

Other Features:

  • Analyze Footwear & Flooring Combinations: Records personnel walking voltages in accordance with ANSI/ESD STM 97.2 Body Voltage measurements as required by ANSI/ESD S 20.20 ESD Program Standard
  • Test & Audit Ionizers: Records and analyses ionization offset and decay time in accordance with ANSI/ESD SP 3.3 and ANSI/ESD STM 3.1 and generates performance reports
  • Other Equipment Applications include voltage generation of chairs, carts and process equipment
  • Records voltage data at 50, 100 or 200 samples per second
  • File recording time at 50 samples/second is 14 minutes
  • Has internal memory for remote data recording, allows downloading at a later time
  • Operates on its own rechargeable battery, which recharges from your computer or supplied AC/DC charger
  • Accepts up to 2.0 volts from any instrument analog output

Technical Specifications

General Specifications

  • Range: 0 to ±20,000 Volts1
  • Input: <±2 Volts
  • Output: USB 2.0
  • Circuit Accuracy: <±1%
  • Sampling Rate: 50, 100 and 200 Samples per second
  • File Size Limit:
    • ≈1 to 15 minutes per file, continuous recording at 50 samples/sec
    • ≈7 minutes at 100 samples/sec
    • 3.5 minutes at 200 samples/sec
  • Power: Rechargeable Lithium-Ion Cylindrical Battery
  • Charger: Universal 90 to 264 Volts
  • Dimensions (LxWxH): 12.7 cm x 7.1 cm x 3.4 cm (5.0" x 2.8" x 1.35")
  • Weight: 6.5 oz (185 grams)
  • Warranty: 1 Year Limited Warranty

1 When connected to a PFM-711A or PFM-711B Field Meter.

Output Accuracy

Voltage Accuracy
100 V ±5%
1000 V ±1%
10.00 kV ±1%
20.00 kV ±1%

Temperature & Relative Humidity Sensor

  • Temperature Range: -25 to + 85°C (-13°F to 185°F)
  • Temperature Accuracy: ± 0.4°C (≈1°F)
  • Response Time: 6 ms in 20 I/min minimum air flow
  • Humidity Accuracy: ±2.0% Rh, 0-100% non-condensing

Lithium-Ion Cylindrical Battery

  • Battery Type: Cylindrical, Rechargeable
  • Technology: Lithium-Ion Technology
  • Manufacturer: VARTA Micro battery
  • Nominal Capacity: 2600mAh
  • Output Voltage: 3.7V
  • Performance Watt-Hour: 9.6Wh
  • Charge Voltage: 4.20V (±50mV)
  • UL Recognition: UL1642
  • Operating Temperature:
    • Discharging: -20°C to 60°C (-4°F to 140°F)
    • Charging: 0°C to 45°C (32°F to 113 °F)

The Rechargeable Lithium ion batteries manufactured by VARTA Micro battery are considered to be UN 3480 Lithium Ion Batteries, and are tested according to 38.3 of the "UN Manual of Tests and Criteria" for compliance with the requirements of special provisions ADR 188, IMDG 188, DOT / 49 CFR § 173.102, and the requirements of IATA DGR packing instruction 965.

More Information
Sell Unit Each
PAC Item Code I339919
MFG Part Number PGA-710B
Brand Prostat
You May Also Be Interested In
©Production Automation Corporation. All Rights Reserved.