Desco 50665

Zero Volt 3-Fan Overhead Ionizing Blower, 120V

The EMIT Overhead Zero Volt Ionizer (ZVI) is a steady-state DC auto-balancing ionizer with integrated closed-loop feedback. It combines the effectiveness of steady-state DC ionization with ease of adjustability, communication capability and the flexibility of a microcontroller-based design to produce a versatile and stable ionization system. Its fans produce extended ionization coverage and are ideal for areas where bench space is limited.

The Overhead Zero Volt Ionizer uses steady-state DC ionization. Steady State DC systems consist of separate negative and positive ion emitters connected by a pair of high-voltage cables to their respective high-voltage power supplies. The spacing between emitters varies depending on the design, and DC power is constantly applied to the emitter points. The ionizer utilizes feedback from the internal sensor grill to continuously adjust the output to maintain balance.

Packaging Includes

  • Overhead Zero Volt Ionizer
  • Power Cord, North American Plug
  • 3 Emitter Point Cleaner Pack
  • Hanging Kit 2 Keys
  • Certificate of Calibration
$1,357.74
  • 3-Fan Overhead Ionizer neutralizes electrostatic charges on insulators and ungrounded conductors in a 2.0' x 5.0' coverage area.
  • Fast Decay Times (< 3.0 seconds at 18"). Discharges (removes) both positive and negative electrostatic charges within the coverage area.
  • ±3 Volt Offset Voltage Balance meets required limits of ANSI/ESD S20.20 (<±35 volts), ANSI/ESD STM3.1 and ESD TR53.
  • Dedicated High Voltage Power Modules with Balance Control at Each Fan. Allows each fan to be tuned to produce the optimum decay and balance in the coverage area.
  • Sealed Plenum Air Flow prevents contamination from being introduced to workstation.
  • Steady State DC Emitters spaced farther apart to prevent ion recombination, increase decay efficiency, and provide a broader coverage area of ionization.
  • Solid Tungsten Emitters maintains sharp point for optimal ionizer performance. Resists oxidation, melting and other damage that dulls the tip of the emitter
  • 9 Speed Fan (195 to 300 CFM) consistent performance at all speeds. Low airflow may be used when working with small moving parts and components that may move with higher airflow.
  • Shielded Bearings retains lubricant and minimizes contamination in the work area.
  • Stainless Steel Housing minimizes foreign objects debris, corrosion, and other contaminations when used in clean or sensitive areas.
  • NIST Calibrated with Certificate Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology.
  • Made in the United States of America

"Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items". (ANSI/ESDS20.20-2007 Foreword)

"In order to mitigate field-induced CDM [Charged Device Model] damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30 cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge." (ANSI/ESDS20.20-2007 section 8.3)

"The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available." (ESD Handbook TR20.20 Ionization, section 5.3.6.1)

"All ionization devices will require periodic maintenance for proper operation. Maintenance intervals for ionizers vary widely depending on the type of ionization equipment and use environment. Critical clean room uses will generally require more frequent attention. It is important to set-up a routine schedule for ionizer service. Routine service is typically required to meet quality audit requirements." (ESD Handbook TR 20.20 section 5.3.6.7 Maintenance / Cleaning)

"Activities that handle items that are susceptible to less than 100 volts HBM may require additional control elements or adjusted limits." [ANSI/ESD S20.20 section 2.0]

Specifications

  • The comparative efficiency of overhead ionizers is determined by a standard test published by the ESD Association: ANSI/ESD STM 3.1. Typical positive and negative discharge times (1000V - 100V) measured using this standard are shown in the "Neutralization (Discharge) Times" section. The performance of the ionizer was measured with the unit positioned as shown, with the fan speed on high and without a filter.
  • Airflow: 9-speed fan 195 to 300 CFM
  • Balance (Offset Voltage): ±3V typical ±5V maximum (65 to 80° F, 15 to 65% RH)
  • Chassis: Stainless Steel
  • Dimensions: 3.9" H x 6.6" W x 42.3" L (9.9 cm x 16.8 cm x 107.4 cm)
  • Emitter Points: 0.05" diameter, pure tungsten
  • Fuse: 400 mA slow blow
  • High Voltage Power Supply: 5.5 kVDC nominal
  • Input Power: AC line power
  • Ion Emission: Steady-state DC with sense feedback
  • Mounting: May be rigid-mounted or suspended from ceiling
  • Ozone: <0.05 ppm
  • Weight: 10 lbs. (4.5 kg)
More Information
Sell Unit Each
PAC Item Code I398713
MFG Part Number 50665
Brand Desco
Input 120V
©Production Automation Corporation. All Rights Reserved.