Desco 19330

Full-Time Monitor

In Stock ESD-Safe
  • Single Workstation Continuous Monitor: Continuously monitors the path-to-ground integrity of one operator, one ESD worksurface, and the electrical ground used to by the monitor.
  • NEW Monitored Ground Terminal: Provides a verified ground point for mats, carts, tools, and other items. Connect with the 09842 Multi-Ground Hub.
  • NEW Light Tower Jack: Connects with 19332 Light Tower Accessory
  • NEW Auxiliary Jack: Connects with 19333 Power Relay Accessory
  • Wave Distortion Technology: Provides stable continuous monitoring (versus pulsed or intermittent) of the wrist strap’s path-to-ground* and the presence of its 1 megohm safety resistor
  • AC Outlet Monitor Circuit: Verifies the wiring of an AC outlet and continuously monitors its path-to-ground integrity; fulfills the ANSI/ESD S6.1 section 6.3.1 requirement
  • Park Delay Timer and Park Snap: Indicates the 8-second delay to disconnect and park the operator wrist cord without creating a false alarm
  • Embedded Relay Terminal: Activates when a failure is reported by the monitor. Integrates with electronic locks, lights, and buzzers.
  • Mat Monitor Switch: Disables the worksurface monitor circuit when used in areas where there is no ESD worksurface
  • Audible Alarm Adjustment: Sets the audible alarm volume from loud to louder
  • Enclosure with Mounting Tabs: Installs in workbench and equipment environments
  • Single-Wire Impedance Design: Meets ANSI/ESD S20.20 in accordance with ESD TR1.0-01-0
  • 1.2 Volt Operator Test Voltage: Reduces the risk of electrical overstress (EOS) for the handling of sensitive components
  • <50 Millisecond Alarm Response Time: Identifies failures and intermittencies
  • Continuous Visual and Audible Alarms: Illuminates green to indicate proper grounding; illuminates red and sounds an audible alarm when intermittent or failed connection occurs
  • Calibration Verification: Use the Desco 98221 Wave Distortion Monitor Verification Tester to check the test limits of Wave Distortion Monitors without removing them from their workstations
  • NIST Calibrated with Certificate Included: Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology.
  • 100-240VAC Input with North American Power Cord: Works with standard electrical systems in North America, Japan, and Asia
  • Made in the United States of America
$278.25

*The ESDA Wrist Strap standard is ANSI/ESD S1.1. The Wrist Strap System required limit per ANSI/ESD S20.20 Table 3 is 0.8 to 1.2 x 106 ohms with product qualification testing per ANSI/ESD S1.1. The test range of the monitored circuit is 500 kilohms to 10 megohms.